Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13670224
| No.13670224
- Product Categories
- Friendly Links
| Information Name: | Jinan HBP-HDXBF constant firefighting equipment |
| Published: | 2015-04-07 |
| Validity: | 365 |
| Specifications: | 9 * 4 * 3 |
| Quantity: | 1000.00 |
| Price Description: | |
| Detailed Product Description: | Usage: Fire booster regulator device is suitable for multi-storey and high-rise construction projects have pressurized the system requirements of the Fire Hydrant and sprinkler systems and other fire water system. Features: 1, diaphragm tank frequency of water supply equipment once inflated sustainable use, to prevent water pollution. 2, the device occupies a small investment, automatically. 3, fault protection, automatic failover. 4, can be networked (according to design) manufacture 5, fire pressure water supply equipment based on standard atlas, 98s205, GA30-92, GA30-2002 and other standards of production and control center. How it works: fire booster regulator device through the membrane to separate gas and water. Inflatable perennial run once used to start the pump inlet water chamber work, water pressure, the gas is compressed air chamber. Set in the high-pressure pump stop, when the water pressure drop, the gas chamber gas expansion, contraction of the diaphragm, oppression effluent water chamber, fill the pump starts at the set pressure low pressure, so again and again, through electrical contacts and automatic control Box control continuous water supply. Installation requirements: 1, before installation of water supply equipment products within the pump abortion should be carefully examined whether the hard thing, to avoid damage to the impeller and the pump is running. 2. When installing piping reasonable amount shall not be allowed on the pump, the pump in order to avoid distortion, affecting the normal operation. 3, tighten the bolt, so as not to affect the performance of the pump vibration when starting. 4, water supply facilities in the inlet and outlet piping pump installation control valve, pressure gauge installed in the vicinity of the pump outlet to control the pump operates within its rated operating conditions to ensure the normal use of the pump. 5, the discharge pipe loaded check valve should be installed outside the gate. 6, the installation of the pump into a rigid connection to install and flexible connection installed. |
Admin>>>
You are the 8091 visitor
Copyright © GuangDong ICP No. 10089450, Water Equipment Co., Ltd., Jiangsu Zhuo game All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 8091 visitor
Copyright © GuangDong ICP No. 10089450, Water Equipment Co., Ltd., Jiangsu Zhuo game All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility

